Aftermarket Replacement V20F / V20P vane pumps

V20 single pumps fitted with a function cover — the V20F flow control cover (main outlet plus tank port, outlet restricted by a fixed orifice) and the V20P priority valve cover (primary, secondary and tank ports with an integral priority valve). Same pump body as the standard V20: ring sizes 6 to 13 covering 19.5 to 42.4 cm³/r, up to 172 bar. The orifice setting (1 or 2 USgpm) or the priority setting is part of the model code, so please send the full code from the nameplate. All units are new aftermarket replacements, quality checked before shipping.
Technical data — V20F / V20P
| Ring | 6 | 7 | 8 | 9 | 11 | 12 | 13 |
|---|---|---|---|---|---|---|---|
| Displacement Vg max (cm³/r) | 19.5 | 22.8 | 26.5 | 29.7 | 36.4 | 39.0 | 42.4 |
| Max speed (rpm) | 3400 | 3000 | 2800 | 2800 | 2500 | 2400 | 2400 |
| Max pressure (bar) | 172 | 172 | 172 | 172 | 172 | 152 | 138 |
| Typical flow (l/min) | 60.9 | 63.2 | 67.0 | 75.0 | 86.7 | 87.1 | 98.4 |
| Max input power (kW) | 21.6 | 22.0 | 24.2 | 26.5 | 28.0 | 26.8 | 29.1 |
Selection notes
F (flow control) and P (priority valve) are the two function covers. The standard cover (S, or omitted) has a single outlet; the F cover splits delivery into a set flow to the work port plus bypass to tank; the P cover feeds the primary circuit first and diverts the remainder to the secondary circuit. The same cover functions continue in the high-pressure V20H version as Cover Type F / P (up to 204 bar). Ring size = rated flow in USgpm at 1200 r/min and 7 bar.
Ordering
The model code must be complete — ring size, mounting, inlet and outlet, shaft and rotation together define the pump. Send the full nameplate code and we will confirm the replacement.
Need the ring size, shaft or port confirmed? Send us the full model code from the nameplate and we will confirm before you order. Contact us
V20 single vane pumps with function covers — V20F flow control cover (main outlet plus tank port with a fixed orifice) and V20P priority valve cover (primary, secondary and tank ports with an integral priority valve). Ring sizes 6–13, 19.5–42.4 cm³/r, up to 172 bar. New aftermarket replacements, quality checked before shipping.
V20F · V20P Vane Pumps
V20 single vane pumps with function covers — V20F flow control cover (main outlet plus tank port with a fixed orifice) and V20P priority valve cover (primary, secondary and tank ports with an integral priority valve). Ring sizes 6–13, 19.5–42.4 cm³/r, up to 172 bar. New aftermarket replacements, quality checked before shipping.
Showing 49–50 of 50 results