V2010 and V2020 Double Vane Pumps: Model Code and Two-Section Selection

V2010 and V2020 double vane pumps: one code, two sections

A double pump puts two cartridge sections on one shaft inside one housing. One inlet feeds both sections, and each section has its own outlet — so you can drive two independent circuits, or combine the two flows. V2010 pairs a V20-class section at the shaft end with a V10-class section at the cover end; V2020 uses V20-class sections at both ends. Both are ordered with a single combined code, and both are built around the same two platforms described on our V10 and V20 single-pump page.

The short version

  • One code covers both sections. The shaft-end section and the cover-end section each have their own ring size and outlet code inside the same string.
  • V2010: shaft-end rings 7–9, 11 and 12–13, cover-end rings 1–7. Weight about 13.6 kg.
  • V2020: shaft-end rings 7–9, 11 and 12–13, cover-end rings 6, 7, 8, 9 and 11 — there is no cover-end ring 12 or 13. Weight about 15.9 kg.
  • Pressure depends on the combination: 138–172 bar across the standard builds.
  • Mounting codes read the opposite way round. On a double pump, 1 = SAE B (4.00 in) and 6 = SAE A (3.25 in). On a single pump it is the other way round.
  • Outlet position is a two-letter code: first letter for outlet 1, second for outlet 2, both measured from the inlet.
  • Order by the complete nameplate code — a double-pump code has two sections’ worth of information in it.

How to read a V2010 / V2020 code

The code runs left to right as: seal prefix, pump letter and series, mounting, inlet, shaft-end ring size, shaft-end outlet, cover-end ring size, cover-end outlet, shaft, outlet positions, design number, rotation — thirteen positions in one string. Take F3-V2010-1F13S3S-1CC-12-L:

Position Value Meaning
Seal prefix F3 Special seal; omitted on the standard build
Pump letter and series V2010 V = vane pump; 2010 = V2010 double pump (V2020 writes 2020)
Mounting 1 SAE B, 4.00 in pilot (6 = SAE A, 3.25 in) — reversed against single pumps
Inlet F Four-bolt flange, shared by both sections: 1.50 in on V2010, 2.00 in on V2020
Shaft-end ring size 13 V20-class section, 13 USgpm at 1200 r/min and 7 bar
Shaft-end outlet S 1.062-12 UN-2B
Cover-end ring size 3 V10-class section on a V2010 (V2020: rings 6, 7, 8, 9 and 11)
Cover-end outlet S .750-16 on a V2010; 1.062-12 on a V2020
Shaft 1 Straight key (11 = spline)
Outlet positions CC Two letters: outlet 1 then outlet 2, each measured from the inlet
Design 12 V2010 design number (V2020 uses 30)
Rotation L Left-hand; omitted for right-hand

Section combinations and performance

Not every ring size pairs with every other. The published combinations are:

Pump Shaft-end ring Cover-end ring Pressure Weight
V2010 7–9, 11, 12–13 1–3, 4–5, 6–7 138–172 bar about 13.6 kg
V2020 7–9, 11, 12–13 6, 7–9, 11 (no 12/13) 138–172 bar about 15.9 kg

Each section’s flow and pressure follow the same rules as the single pumps: ring size is a flow class in USgpm at 1200 r/min and 7 bar, and maximum pressure falls as the ring size rises. Because the two sections share one shaft, the shaft load is the sum of both — that is the main reason to check the combination rather than swap in the nearest sizes.

Outlet positions: the two-letter code

Single pumps use one letter (A–D). Double pumps use two, written together: the first letter gives outlet 1 (shaft end), the second gives outlet 2 (cover end), and both are measured relative to the inlet. The second letter follows two different tables depending on the series, so a position code copied from a V2010 does not automatically mean the same thing on a V2020.

Four things that go wrong when ordering

  • The mounting code is reversed. Double-pump 1 is SAE B; single-pump 1 is SAE A. Reading a double-pump nameplate with single-pump habits gets the flange wrong.
  • Only one section’s rings are quoted. Both sections matter, and the cover end has its own set — V2020 stops at ring 11.
  • The position code has two letters. Quoting one letter (or one letter’s worth of meaning) loses the second outlet’s orientation.
  • Foot brackets are not in the code. Where a mounting foot is needed, it is a separate kit, not a code position.

Which one do you need?

Start from the two flows the machine needs. If the two circuits are unequal — a large main flow plus a smaller auxiliary one — V2010 is usually the fit. If both circuits need comparable V20-class flow, take V2020. The builds in this family are rated 138–172 bar depending on the combination; if your machine works above that band, send us the working pressure together with the nameplate code and we will confirm what suits it.

You can browse the range directly: V10 · V20 · V200 · VTM42 series, V2010 double pumps and V2020 double pumps.

Send us the nameplate code

A double-pump code carries two sections, so it is easy to transcribe half of it. Send the complete string from the nameplate and we will confirm the replacement — both ring sizes, both outlets, the position code and the rotation — before you order. All units we ship are new aftermarket replacements, quality checked before dispatch. Contact us with your code.