New Aftermarket A4VSO180DFR/30R-PPB13N00E Axial Piston Pump

$1100

SKU: R902406262 Category:

Model code — A4VSO180DFR/30R-PPB13N00E

Decoded position by position against the RE 92050 model code table (14 positions). Positions 09–14 form one continuous options string without separators; this unit reads as follows:

Position Value Meaning
01 Hydraulic fluid — omitted — mineral oil + HFD
02 Unit A4VS swashplate variable pump (350 bar nominal / 400 bar peak)
03 Boost pump — omitted — no boost pump (L only on NG750)
04 Mode O open circuit
05 Size (NG) 180 nominal size NG180
06 Controller DFR pressure and flow control (X-T open)
07 Design series 30 Series 30 (current main series)
08 Rotation R clockwise, viewed from the drive shaft end
09 Seal material P NBR body with PTFE shaft seal (for HFA / HFB / HFC)
10 Drive shaft P straight key shaft, DIN 6885
11 Mounting flange B ISO 3019-2 metric 4-hole (NG40–500)
12 Work ports 13 standard: SAE flange on B/S side, 90°, metric threads
13 Through-drive flange N00 no through drive
14 Filtration — omitted — no filter
Additional code E not detailed in the reference table — we confirm this against the order before shipping

Note: P in position 09 is a seal code, while P in position 10 is a straight key shaft — the same letter has two different meanings. H in position 11 is the ISO 3019-2 eight-hole flange (NG500 / 750 / 1000).

Product overview

New aftermarket A4VSO180DFR/30R-PPB13N00E axial piston pump. Swashplate-type variable displacement pump for open circuit, from the A4VSO Series 10/11/30 family. Size NG180, geometric displacement 180 cm3/rev.

Nominal pressure 350 bar, peak pressure 400 bar. Maximum drive speed 1800 rpm at Vg max; flow approx. 270 L/min at 1500 rpm.

This listing covers the A4VSO 180 DFR version. Supply is as a new aftermarket replacement unit, quality checked before shipping. Because the full model code defines mounting, seals, shaft and ports, please send us your complete nameplate code before ordering and we will confirm the exact configuration.

Control: DFR pressure-flow controller

The DFR control combines pressure limitation with flow matching (load-sensing). In the basic position flow is delivered at pump pressure; when no flow is needed, the pump swivels back to reduce losses.

Other sizes and controls

Other A4VSO sizes (NG40 to NG500) and controls are available on request. Send us your requirements.

Other models on this size

This NG180 pump is also available in these variants:

Series overview: A4VSO Piston Pump. Other sizes and controls (NG40 to NG1000): Piston Pumps.

Not sure what you need? Send us the full code from the nameplate and we will confirm the correct configuration. Contact us

Reviews

There are no reviews yet.

Be the first to review “New Aftermarket A4VSO180DFR/30R-PPB13N00E Axial Piston Pump”