Model code — A10VNO85DRS/53L-VRD12K01
Decoded against the official ordering code of this series (series 53 uses 12 positions, in the order of positions 02–13 of series 31). This unit reads as follows:
| Field | Value | Meaning |
|---|---|---|
| Axial piston unit | A10VNO | A10VNO swashplate variable pump (open circuit) |
| Size (NG) | 85 | nominal size NG85 |
| Control | DRS | pressure and flow control (X-T closed) |
| Series | 53 | series 53 |
| Rotation | L | counter-clockwise, viewed from the shaft end |
| Seals | V | FKM fluoroelastomer (modern standard) |
| Drive shaft | R | spline, high torque |
| Mounting flange | D | SAE 4-hole |
| Work ports | 12 | metric flange seat, fixed metric threads (DIN 13) |
| Through drive | K01 | through drive (coupling and auxiliary pump matching, see §5.3 of the reference) |
| Solenoid connector | — | omitted — none |
Product overview
New aftermarket A10VNO axial piston variable pump, Series 53, swashplate design for open circuit. Complete model code: A10VNO85DRS/53L-VRD12K01. Size NG85, nominal displacement 85 cm³/rev. Nominal pressure 210 bar, maximum pressure 250 bar. Direction of rotation L (counter-clockwise, viewed on the drive shaft). Quality checked before shipping. Contact us to confirm exact configuration and availability before ordering.
Control: DRS pressure and flow controller (load-sensing, X-T plugged, with flushing)
In addition to the pressure controller function, an adjustable orifice is used to control the differential pressure and therefore the pump flow. The DRS version has X-T plugged with a flushing function; the LS line must be unloaded in the system. With all controller combinations, reduction of Vg has priority.
- Basic position in depressurized state: Vg max.
- Setting range up to 210 bar — standard is 210 bar.
- For pressure controller data, see the DR pressure controller.
Other control options on this size
This 85 cm³ Series 53 pump is also available with other controls:
- A10VNO85DRF/53L-VRC11N00-S — DRF pressure and flow controller (load-sensing, X-T open)
- A10VNO85DRSC/53R-VSC12N00-S — DRSC pressure and flow controller, X-T plugged without flushing
- A10VNO85ED72/53L-VRC12G70P — ED72 electrohydraulic pressure control, negative control (24 V)
- A10VNO85EP2D/53L-VWC12K04P — EP2D electro-proportional pressure control, positive control (24 V)
Ordering
Send us the complete model code from the nameplate of your existing pump, or the machine model — we will confirm the correct size, control and configuration before you order.
Series overview
All models in this series: A10VNO Series 53. Parent range: A10VO Piston Pump.
Not sure about the fit? Contact us with the full nameplate code and we will confirm before you order.




Reviews